Customization: | Available |
---|---|
Condition: | New |
Certification: | ISO, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:SMART2-40A/50A/60A -series | 40A | 50A | 60A | 80A | 100A | |||||
Charge Mode | Maximum Power Point Tracking | |||||||||
Method | 3 stages: fast charge(MPPT),constant voltage, floating charge | |||||||||
System Type | DC12V/24V/48V | Automatic recognition | ||||||||
System Voltage | 12V system | DC9V~DC15V | ||||||||
24V system | DC18V~DC30V | |||||||||
48Vsystem | DC36V~DC60V | |||||||||
Soft Start Time | 12V/24V/48Vsystem | ≤10S | ||||||||
Dynamic Response Recovery Time | 12V/24V/48Vsystem | 500us | ||||||||
Conversion Efficiency | 12V/24V/48Vsystem | ≥96.5%,≤99% | ||||||||
PV Modules Utilization Rate | 12V/24V/48Vsystem | ≥99% | ||||||||
Input Characteristics | ||||||||||
MPPT Working Voltage and Range | 12V system | DC18V~DC150V | ||||||||
24V system | DC34~DC150V | |||||||||
48V system | DC65~DC150V | |||||||||
Low Voltage Input Protection Point | 12V system | DC16V | ||||||||
24V system | DC30V | |||||||||
48V system | DC60V | |||||||||
Low Voltage Input Recovery Point | 12V system | DC22V | ||||||||
24V system | DC34V | |||||||||
48V system | DC65V | |||||||||
Max DC Voltage | 12V/24V/48V system | DC160V | ||||||||
Input Overvoltage Protection Point | 12V/24V/48V system | DC150 | ||||||||
Input Overvoltage Recovery Point | 12V/24V/48V system | DC145V | ||||||||
Max. PV Power | 12V system | 570W | 700W | 900W | 1136W | 1420W | ||||
24V system | 1130W | 1400W | 1700W | 2272W | 2840W | |||||
48V system | 2270W | 2800W | 3400W | 4454W | 5680W |